...
| Portuguese | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Technical Bulletin: Field CVC_CODMUN Occurrence Improvement Summary The system validation for the City Code field (CVC_CODMUN) has been removed when used in the Brazil environment. ID of Ticket TESJKB Products
Modules
Portals
Countries
Operating System
Database
Name + Source CVC - Accountant Register Compatibility Tool Adjustments Yes Referential Integrity No Patch Application No Compatibility Tool 1 - UPDCTB Implementation Procedures To make this improvement feasible, you must first apply this ticket's update package (Patch). Before running the compatibility tool UPDCTB, you must: a) Backup the database of the product to be executed by compatibility tool (\PROTHEUS11_DATA\DATA directory) and SXs data dictionaries (\PROTHEUS11_DATA\SYSTEM directory). b) The above directories are the default installation of Protheus®, and you should edit them to match the product installed at your company. c) This routine must run in exclusive mode; that is, no user should be using the system. d) If data dictionaries have customized indexes (created by the user), be sure to identify them by their nicknames prior to running the compatibility tool. If the compatibility tool needs to create indexes, it will add them from the original order installed in Protheus®, which can overwrite custom indexes if they are not identified by the nickname. e) You must run the compatibility program with Referential Integrity deactivated*.
To correctly update the data dictionaries, make sure the date on the compatibility tool is equal to or after 4/03/2012. 2. Click Ok to continue. 3. After confirmation, a window is displayed for selecting the compatibility tool.. Select the program U_UPDCTB. 4. When you confirm it, a warning message is displayed about the backup and the need to run it in exclusive mode. Confirm it to start the processing. The first execution step is file preparation, in accordance with the message displayed on-screenonscreen. 5. Afterwards, the window Update Completed is displayed with the history (log) of all updates processed. In this updating log, only the fields updated by the program are presented. The compatibility tool creates fields that do not exist in the data dictionary yet. 6. Click Save to save the history (log) displayed. 7. Click Ok to close the process. Adjustments Description
The size of fields that have groups may vary according to the environment in use. Procedures for Configuration Utilization Procedures Technical Data
Notes |